FirstRig
firstrig.com

Diagnose 20 of 29 Acquisition quality

Flats made it worse

After calibration, dust donuts appear doubled, or the corners come out brighter than the center.

A labeled frame from our own archive, with its acquisition data, is coming to this page.

At 100 %

A calibrated frame beside the raw one. A donut that now appears twice, or corners lighter than the middle.

Causes, most likely first
  1. Focus or rotation changed between lights and flats

    Flats calibrate the dust and vignetting of one optical setup. Move the focuser or turn the camera and they calibrate a different one, so the dust shadows land in the wrong place.

    FixShoot flats before touching focus, rotation or the camera. With per-filter focus offsets or a rotator, match the positions the lights used.

    Session Checklist
  2. Flats over- or under-exposed

    Overexposed flats run into the sensor's nonlinear range, and underexposed ones are dominated by their own noise. Either way the correction comes out wrong.

    FixExpose flats to a measured ADU target, counted from the offset up, rather than by eye. On a color camera, read the green channel.

    Session Checklist
  3. Panel flicker

    An LED panel's PWM flicker beating against short exposures makes the flats uneven, and that unevenness is divided into every light.

    FixDim the panel so the flat exposures are long enough to average the flicker out.

    Session Checklist
  4. Bias used instead of dark flats

    Flats have to be calibrated by something, and on CMOS the short-exposure frame is where bias and dark behavior part company.

    FixShoot dark flats at the flats' exposure, gain and offset, and at their temperature on a cooled camera.

    Sub-Exposure & Calibration Planner
Looks like, but isn't

The atlas lists no look-alike for this one.

One frame can't tell you

A calibrated frame shows the fault. Which cause made it needs the flats themselves: their exposure level, and whether focus or rotation moved before they were shot.

How to confirm the fix

Calibrated frames with no doubled dust, and corners that match the center under a hard stretch.

Contested
Contested

Bias versus dark flats on CMOS is argued both ways. Testing reported by AAVSO found short CMOS darks carry structure bias frames miss, which is why we default to dark flats. Many imagers calibrate flats with bias on sensors whose short exposures are clean, without trouble. Compare a bias with a dark flat from your own camera; the answer is per sensor.

In the symptom picker

  • Dust donuts appear doubled after flats are appliedweight 3
  • The corners come out brighter than the center after calibrationweight 3
  • It appeared, or got worse, after applying flatsweight 2
Open the picker with its signature ticked