Diagnose · the failure atlas
What went wrong in this frame
Tick what you see. The 29 failure modes that could produce it are ranked by how much of each one's signature you ticked, with the look-alikes to rule out. Each mode's page has the causes in order of likelihood and the fix for each, cheapest first.
It ranks what you tick against written signatures. It does not look at your image, and some failures need the night's logs to tell apart, which each page says.
What you see
Tick everything that fits, at full size where it says so. You don’t need to know the cause.
Ranked failure modes
Tick what you see and the failure modes that produce it are ranked here, each with the look-alikes to rule out and a link to its page.
All 29 failure modes
Grouped by where they tend to turn up, on a first rig or on a new one: the mechanics of tracking and focus, the quality of the data, and processing.
Acquisition mechanics
usually months 1–3 · 7 modes- Elongated starsEvery star in the frame is stretched into a short oval, all pointing the same way. The center looks as bad as the corners.
- Star trailsStars are long streaks, many times longer than they are wide, with no round core at either end.
- Stars trail partway through a subIn one frame, every star is a sharp dot with a streak attached. Something moved the rig partway through the exposure.
- Worse after the meridian flipGuiding and star shapes are fine until the flip, then get worse at once and stay worse for the rest of the night.
- Field rotationStars are short arcs curving around one point in the frame, longer toward the edges.
- Bloated, soft starsEvery star is round but fat, across the whole frame, with no stretch in any direction.
- Unwanted diffraction spikesBright stars carry spikes where the telescope should not make them: any spike from a refractor, or extra spikes at an odd angle.
Acquisition quality
usually months 3–12 · 13 modes- Triangular corner starsUnverifiedCorner stars are triangles or little comets while the center is sharp, and all four corners look about the same.
- One side softOne edge or one corner is consistently worse than the rest of the frame, and the others are fine.
- ComaStars stretch outward from the center, more toward the edges, flaring like seagulls. The center is sharp.
- VignettingThe corners are darker than the center, evenly, in a ring around the middle of the frame.
- Halos around bright starsBright stars have a ring or a soft glow around them, larger than the star itself. Faint stars look normal.
- GradientsA smooth ramp in brightness runs across the frame, brighter on one side.
- Amp glowA structured glow sits in one corner or along one edge, the same in every frame.
- Walking noiseFaint diagonal streaks of noise run through the stacked image, all at one angle.
- BandingHorizontal or vertical stripes cross the background.
- Lost to cloudThe number of stars in each sub collapses while the stars that remain stay as sharp as before.
- Satellite trailsA single sharp line crosses one frame, and the stars around it are unaffected.
- Dew on the opticsStars get softer and halos around bright stars grow through the session, sub after sub.
- Flats made it worseAfter calibration, dust donuts appear doubled, or the corners come out brighter than the center.
Processing
usually year 1 onward · 9 modes- Green castThe whole image has a green tint, worst in the background.
- Clipped blacksThe background is pure black, and the faint outer nebulosity is gone.
- Over-stretchedThe image is washed out and low in contrast, with a bright gray background.
- Star bloat from stretchingStars grow large and pale as the nebula is stretched.
- Dark halosA dark ring surrounds stars, or runs along the edges of bright structure.
- Plastic backgroundThe background is smooth and blotchy, like wax, with no grain.
- Color noiseUnverifiedColored speckle covers the background: single pixels in different colors where the sky should be even.
- Neon colorsColors are oversaturated and unnatural across the image.
- Edge artifactsOdd frames, streaks or stacking seams run along the borders of the stacked image.
How this is computed
score(mode) = sum of weight(symptom), over the ticked symptoms the mode lists
weight = 3 the mode's own signature
2 its look-alike test, or a strong companion sign
1 a weak sign it shares with look-alikes
order = score, high to low; ties in the atlas's own orderEvery symptom a failure mode can produce carries a weight, and a mode’s score is the sum of the weights you ticked, shown against the most it could reach. The weights are ours. They were set so that the distinctions the atlas draws come out right, such as fat stars that look fine in the unstretched stack ranking star bloat from stretching ahead of focus. No measured data is behind them yet.
Ties go to the mode the atlas lists first, which runs in the order failures usually appear. The ranking is a starting point for the mode pages, which carry what a single frame cannot tell you.
Source: docs/10-failure-atlas.md § 2 (signatures, causes, look-alikes) and § 4 (each row is a rule for the Diagnostic). 39 symptoms; content and ranking in packages/data/src/diagnose, unit-tested.
Last updated